Product Description
Backed by rich experience and knowledge in this domain, we manufacture and export best quality of Electromagnetic Flow Meter. Widely used to measure the flow rate of liquids, these flow meters are made by our skilled professional using high-end quality materials & components. These flow meters are functionally advanced in nature and reckoned for among our clients for their stability, high strength and excellent durability. We duly check Electromagnetic Flow Meter on quality norms, before supply to clients.
Technical Parameters
Nominal Diameter (DN)
| Unit
| Single-jet
| Multi-jet
|
mm
| 15
| 20
| 15
| 20
| 25
| 40
| 50
|
Inches | 1/2
| 3/4
| 1/4
| 3/4
| 1
| 1 1/2
| 2
|
Starting Flow Rate
| I/h | 14
| 18
| 14
| 18
| 25
| 70
| 80
|
Maximum Admissible Temp.
| C | 45 C (Optional 90C)
|
Maximum Admissible Working Pressure
| bar (kg/cm3)
| 10
|
Test Pressure - P
| bar (kg/cm2)
| 16
|
Qmax
| Max. Peak flow +- 2% Accuracy
| m3/hr | 3.0
| 5.0
| 3.0
| 5.0
| 7.0
| 20.0
| 30.0
|
Qn
| Nominal flow +- 2% Accuracy
| m3/hr | 1.5
| 2.5
| 1.5
| 2.5
| 3.5
| 10.0
| 15.0
|
Qt.
| Transitional flow +-2% Accuracy
| I /h | 120
| 200
| 120
| 200
| 280
| 800
| 1200
|
Qmin
| Minimum flow +- 5% Accuracy
| I / h | 30
| 50
| 30
| 50
| 70
| 200
| 300
|
Head Loss at
| Qmax
| m | 7.0
| 7.0
| 6.5
| 7.5
| 9.0
| 5.0
| 4.8
|
Qn
| m | 1.7
| 1.8
| 1.7
| 1.9
| 2.3
| 1.3
| 1.2
|
Dimension
|
Length (without Tail Pipes)
| mm
|
|
| 165
| 190
| 260
| 300
| 330
|
Length (with Tail Pipes)
| mm
| 250
| 290
| 250
| 290
| 380
| 430
| 470
|
Salient Features
- Velocity type meter
- Direct magnetic transmission
- Class B ISO 4064
- Superior accuracy and long-term reliability
- Highly sensitive to low flow rate and very accurate over its entire flow range.
- Low head loss.
- Vacuum sealed. leak proof and dry Totaliser.
- Maintenance-free long working life.